Tutorial Mobile Legionella Laboratory

This tutorial consists essentially of the above available Video. The use of the Mobile Legionella laboratorie for measuring the concentration of legionella is explained. For the successful measurement it is required, meticulously follow the steps shown. That is why it is recommended, several times to watch the video and to make personal notes. Have fun seeing and much success in measuring!

Seminar chlorine dioxide generators

Seminar for measurement of disinfectants in water with the following contents: Introduction water disinfection, Measurable disinfectant, Connection pH and disinfecting action of chlorine and bromine, Principle of amperometric measurement with and without membrane, Construction membrane-covered sensors, Conditions of measurement, Cross-sensitivities, Causes of any disturbance of the measurement, Signal transmission and signal types, Calibration of the connected controller, Maintenance and reconditioning of the electrochemical system of sensors.

Seminar controller DCW400ip – INTERNET OF WATER

Seminar zu Regler DCW400ip – INTERNET OF WATER; Introduction water disinfection, Measurable disinfectant, Connection pH and disinfecting action of chlorine and bromine, Influence of trichloro-isocyanuric acid on the measured value, Conventional methods for producing chlorine dioxide, Signal extracting with different sensor types, Available modules for the device and available measurement parameters, Connecting the device to the Internet, Advantages of the internal Web server, Activation of the modules, Setting of the sensor to the module, Configuration of the controller, Output configuration, Configuration of target value, Warning levels and alarm levels, Calibration of the instrument and the DPD measurement configuration of the timer functions, Configuration of all inputs on the main board and use of data, User Management, Email Management, evaluate statistical data,

Seminar membrane-covered amperometric sensors

Seminar for measurement of disinfectants in water with the following contents: Introduction water disinfection, Measurable disinfectant, Connection pH and disinfecting action of chlorine and bromine, Principle of amperometric measurement with and without membrane, Construction membrane-covered sensors, Conditions of measurement, Cross-sensitivities, Causes of any disturbance of the measurement, Signal transmission and signal types, Calibration of the connected controller, Maintenance and reconditioning of the electrochemical system of sensors.

If the chlorine reaches its limits!

Contamination of sand filters (Biological contamination of the filters) is a growing problem, particularly through the use of activated carbon. The newspaper article offers solutions and ideas. Disinfection against Filterverkeimung. With a water treatment and disinfection after the letters of DIN everything is done? No! Where does the air from your air flushing? If you do not know it or you can smell during the flushing, then you should urgently and carefully read to the end.

Again, this post assumes, that flocculation and filtering are set optimally and work. The hints, which the Federal Environmental Agency in the notice: "Hygiene requirements for pools and monitoring" 2014 is about the quality of filtering given, we had in a previous text in the October 2016 implemented.

Document Unfallverhütungsvorschrift chlorination of water

posted in: Documents 0

Unfallverhütungsvorschrift Chlorination of water UVV d5 with markings, Scope § 1. (1) This accident prevention regulation applies to - chlorination and procedures, where chlorine or chlorine compounds are introduced into water, - hold spaces of chlorination plants, - storage rooms for the used materials to chlorination.
to § 1 Abs. 1: For transportable pressure receptacles shall otherwise the "Regulation on transportable container-filling stations for compressed gases (Druckbehälterverordnung)“.
(2) This accident prevention regulation does not apply to - stationary pressure vessels, - laboratory work with chlorine or chlorine compounds.

Document List of treatment materials and disinfection methods

posted in: Documents 0

Announcement of the list of treatment substances and disinfection procedures in accordance with § 11 the drinking water regulations
– 19. Modification - (Update: December 2017), Below the list of treatment materials and disinfection procedure is in accordance with § 11 the drinking water regulations (TrinkwV 2001)1 as amended by 19. given change known. 1 Introduction: During recovery, Treatment and distribution of drinking water may only use such substances treatment and disinfection, only those methods are applied, contained in the present list. Exceptions apply only if there is an approval of the Federal Environment Agency under the provisions of § 12 TrinkwV 2001. Preparation materials are all substances, the in attracting, Preparation and distribution of potable water can be used up to the discharge point and which may change the composition of the extracted drinking water (§ 3 Number 8 TrinkwV
2001).

error: Content is protected !!